Product Details:
Payment & Shipping Terms:
|
High Light: | environmental test chamber,temperature and humidity chamber |
---|
Small size high and low temperature (hot-humid) testing chamber/ small size high & low temperature humidity testing box
Small size high and low temperature (hot-humid) testing chamber | |||||||||
Model | MT80A-40 | MT80A-65 | MH80A-40 | MH80A-65 | |||||
Nominal volume (L) | 80 | ||||||||
Performance | Temperature range | (-40℃~+150℃) | (-65℃~+150℃) | (-40℃~+150℃) | (-65℃~+150℃) | ||||
Humidity range | 25~98%RH | ||||||||
Temp. Fluctuation | ≤1℃ | ||||||||
Temp. Deviation | ≤±2℃(≤+200℃),≤±3℃(+200℃~+300℃) | ||||||||
Humidity deviation | ±3%RH(≤75%RH),±5.0%RH(≤75%RH) | ||||||||
Temp. Rising time | (-40℃~+150℃) | (-65℃~+150℃) | (-40℃~+150℃) | (-65℃~+150℃) | |||||
≤60min | |||||||||
Temp. dropping time | (+20℃~-35℃) | (+20℃~-60℃) | (+220℃~-35℃) | (+20℃~-60℃) | |||||
≤60min | ≤80min | ≤60min | ≤80min | ||||||
Internal demension mm | W | 400 | |||||||
H | 500 | ||||||||
D | 400 | ||||||||
Extenal demension mm | W | 600 | |||||||
H | 1323 | ||||||||
D | 994 | ||||||||
Method of temp. and humid. adjustment | BTC Coordinate temperature control mode | BTHC Coordinate temperature & humidity control mode | |||||||
Operating enviorment | Temp.: 5~35℃, relative humidity: ≤85%RH, Atomoshperic pressure: 86~106KPa | ||||||||
Material | External material | Galvanized sheet on both side, plastic-spray surface treatment. | |||||||
Inner chamber material | Stainless steel | ||||||||
Isolation material | Hard PU foam+ glass fiber wool | ||||||||
Adjustor | Heater | Nickel-chromium alloy wire heater | |||||||
fan motor | axial flow fan motor | ||||||||
Cooling method | Mechanical compression binary folding refrigeration (air cooling) | ||||||||
Compressor | Full sealing compressor | ||||||||
Refrigerant | R404a/R23 | ||||||||
Controller | Display | 3.5"LCD touch screen | |||||||
Way of running | Fixed parameter and programable | ||||||||
Way of setup | By touchscreen | ||||||||
Program volume | 20 group programmable, each group 100 line | ||||||||
Setting range | According to the working temp. of the chamber to adjust ( upper limit +5℃, lower limit -5℃) | ||||||||
Display resolution | Time: 0.1min; Temp. : 0.1℃; | ||||||||
Input | platinum resistor | ||||||||
Control method | Anti - integral saturated PID, BTC Coordinate temperature control mode | ||||||||
Water supply | way of supply | —— | water pump | ||||||
Built-in water storage capacity. | 15L | ||||||||
Water quality | electrical resistivity >500Ω*m | ||||||||
Power source | AC220V±10% 50HZ±10% single phase double wire + protection earth wire | ||||||||
Max. current of power source (A) | 16 | 16 | 21 | 21 | |||||
Power (kW) | 3.1 | 3.1 | 4.6 | 4.6 | |||||
Weight (kg) | 90 | 90 | 95 | 95 | |||||
Standard configuration | Hour meter 1 pcs, sample frames 2 sets, power cable (5m) 1 pcs | ||||||||
Optional accessories | Rubber cover for cable hole, sample frame, wet-ball gauze, water purifier | ||||||||
Safty device | Leakage protector, Over heating protector inside the chamber, overload protector for the fan motor, compressor over-pressure protection, over-flow protection, Phase order protection, Dry heating protection, Waterway protection and etc… | ||||||||
Contact Person: Mrs. Lihy
Tel: 86-18620810595
Fax: 86-20-86985656